'Unexpected Error' Is Coming When We Open Instance LOV In MSCA End Resource Transaction with Multiple resources
(Doc ID 2331141.1)
Last updated on JULY 15, 2020
Applies to:
Oracle Process Manufacturing Process Execution - Version 12.2.6 and laterInformation in this document applies to any platform.
Symptoms
On : 12.2.6 version, OPM Mobile
When attempting to open LOV in MSCA
the following error occurs.
ERROR
-----------------------
Unexpected Error.
STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. Release the batch from the forms.
2. Choose MES for Process Manufacturing mobile
3. Release step.
4. Start resource with instance 1
5. Next --> Start Resource with instance 2.
6. Choose End resource.
7. Error is thrown .
Changes