Cycle Count Approval for Items that are Tracked in Primary and Secondary UOM Fail with ORA-06502:PL/SQL:numeric or value error INV_CC_WORKFLOW_APPRV Procedure CC_Check_Onhand
(Doc ID 2727268.1)
Last updated on SEPTEMBER 06, 2021
Applies to:
Oracle Inventory Management - Version 12.2.9 and laterInformation in this document applies to any platform.
Symptoms
When attempting to approve a Cycle Count entry for an item that track On-hand inventory in Primary and Secondary UOM, the following error occurs.
ERROR
ORA-06502:PL/SQL:numeric or value error:character to number conversion error in Package INV_CC_WORKFLOW_APPRV Procedure CC_Check_Onhand
User Click Ok to the form error, the application raise the following note:
Note
100501: non -ORACLE exception
STEPS
The issue can be reproduced at will with the following steps:
1. User navigate to the Cycle Count Approval form where user can see there is a pending count waiting for approval for item XYZ123.
Adjustment
System Qty Secondary System Qty UOM Qty Secondary UOM Secondary Qty
0 0 EA 300 KG 1.89873
0 0 KG 15.2 KG 15.2
This cycle count show adjustment in primary and secondary quantity for first count (count in primary) and on second count, counted in secondary UOM.
2. User proceed to approve the first record. The record is approved with no issue, however, when user attempt to save the approved cycle count record, the application raise the error.
WHAT IS WORKING
The Cycle Count Approval process works fine for items that have no secondary UOM.