My Oracle Support Banner

MES Touchscreen Change Scale Selection Errors With 'This request was not processed...' When Using a Scale With a Space In the Name (Doc ID 2734808.1)

Last updated on DECEMBER 07, 2020

Applies to:

Oracle MES for Process Manufacturing - Version 12.2.8 and later
Information in this document applies to any platform.

Symptoms

On : 12.2.8 version, Touchscreen

MES Touchscreen Change Scale Selection Errors when using a scale with a space in the name.
This error does not occur when selecting the scale in the 'Dispensable Material' function, only the 'Touchscreen Dispensable Material'
This error seems to only be produced if there is a space ' ' in the scale name.
Workaround is to remove spaces from the device name.

ERROR
-----------------------
This request was not processed as the request URL OA.jsp?page=/oracle/apps/gmo/dispense/kiosk/webui/DispenseMtlPG&retainAM=Y&INIT=N&RESPONSE=Y&LOV_TYPE=SCALE_CHANGE_EVENT&LOV_ACTION=APPLY&targetDeviceLov=&targetDeviceID=null&srcDeviceID=24&srcDeviceLov=Scale 3&_ti=520397421 contained potentially illegal or un-encoded characters. Please try again by submitting a valid URL or contact your systems administrator for assistance.




STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. Touchscreen Dispensable Material function in MES
2. --> Select the device --> Accept (Green box)



Changes

 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution
References


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.