SvcComponentException:Validation failed for the following parameters "PROCESSOR_READ_TIMEOUT' Causing Workflow Deferred Agent Listener To Be Down (Doc ID 604775.1)

Last updated on DECEMBER 19, 2015

Applies to:

Oracle Workflow - Version 11.5.10.2 to 11.5.10.2 [Release 11.5.10]
Information in this document applies to any platform.

Symptoms

On 11.5.10.2
when attempting to start Workflow Deffered Agent listener,
the following error occurs:

Status information: This automatic Service
Component has been restarted the maximum of 10 times after stopping with error. Thus, it has been
system deactivated -> oracle.apps.fnd.cp.gsc.SvcComponentContainerException: Could not start
component; performing rollback -> oracle.apps.fnd.cp.gsc.SvcComponentException: Validation
failed for the following parameters -> {PROCESSOR_READ_TIMEOUT=Value is required and must be a number }. Parameters were -> {PROCESSOR_OUT_THREAD_COUNT=0, PROCESSOR_ERROR_LOOP_SLEEP=60,
LISTENER_PROCESS_EVT_COUNT=500, PROCESSOR_IN_THREAD_COUNT=1, PROCESSOR_LOOP_SLEEP=120,
PROCESSOR_MAX_ERROR_COUNT=10, PROCESSOR_MAX_LOOP_SLEEP=0, COMPONENT_LOG_LEVEL=5,
PROCESSOR_READ_TIMEOUT_CLOSE=Y, PROCESSOR_READ_TIMEOUT=Y}


The issue can be reproduced at will with the following steps:
1. Try bring up Workflow Deffered Agent listener service component from OAM.
2. Fails with above error.


The issue has the following business impact:
Due to this issue, users cannot use Workflow services.