Collection Element of Type SEQUENCE is Defaulted as AUTOMATIC after Upgrade from 11.5.9 (Doc ID 989235.1)

Last updated on AUGUST 26, 2015

Applies to:

Oracle Quality - Version 11.5.10.0 to 12 [Release 11.5 to 12]
Information in this document applies to any platform.

Symptoms

On : 12.0.4 version, When attempting to enter results in Enter Quality results form for a nonconformance plan containing sequence element after upgrade from 11.5.9, the collection element remains as Automatic and after entering other elements,  following error occurs.

APP-QA-16262: One of the variables used in the actions is a sequence element. Its value is not known at this time.
APP-QA-16115: Failed to perform SQL Statement:
SELECT Automatic from dual
Please check the 'Assign a Value' action in the 'Collection Plans' form


After OK it’s impossible to save the record as the same last two errors keep appearing!

The issue can be reproduced with the following steps:
1. (N) Quality -> Results -> Entry -> Enter Quality Results (QLTRSMDF)
2. enter results and save
3. observe the error displayed.

Cause