My Oracle Support Banner

STDCUSVW - Limit Tab - Line Details Button Click Launches GWDFACLT Instead Of GEDFACLT (Doc ID 2609751.1)

Last updated on FEBRUARY 28, 2020

Applies to:

Oracle FLEXCUBE Universal Banking - Version 14.0.0.0.0 and later
Information in this document applies to any platform.

Symptoms

On : 14.0.0.0.0 version, Implementation Support

ACTUAL BEHAVIOR
---------------

In STDCUSVW - Limit tab - Line details Button click launches GWDFACLT instead of GEDFACLT


EXPECTED BEHAVIOR
-----------------------

In STDCUSVW - Limit tab - Line details Button click should launche GEDFACL screen.

STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. On click of Line details button in STDCUSVW Screen, System is launching GWDFACLT Screen based on ELCM_SETUP_MODE = ‘S’ (STDCUSVW_KERNEL.js).
2. Hence the Screen is getting hung. System should launch GEDFACLT Screen.
3. Customer tried doing necessary changes in STDCUSVW_KERNEL.js to test, System is now launching GEDFACLT screen but it still fails to query the data.
4. This is due to wrong value assigned in STDCUSVW_KERNEL.js to variable ScreenArgs[LIAB_NO] for GEDFACLT launch
5. System should assign LIAB_NO(instead of LIAB_ID) from the screen.
6.Post changing that GEDFACLT Screen launched successfully

BUSINESS IMPACT
-----------------------
The issue has the following business impact:

Cause