My Oracle Support Banner

FT: MT103 Cannot Be Authorized -error MS-00202 (Doc ID 2831342.1)

Last updated on JANUARY 03, 2022

Applies to:

Oracle FLEXCUBE Universal Banking - Version 12.3 to 12.4.0.0.0
Information in this document applies to any platform.

Symptoms

On : 12.3 version, Production Support-SET

FT: MT103 cannot be authorized

Please be informed that our client has faced an issue with an incoming MT103 in Authorization. From our investigation we have noticed that an MT910 message has been received before the MT103, thus the logic of the package does not allow it to proceed.
The message to be taken into consideration is MT103, despite the fact of which message will be received first.


ERROR
-----------------------
MS-00202


STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1)Upload MT910
2)Upload MT103
3)Save the incoming message
4)Authorize the incoming (error MS-00202)

Changes

 Code added to validate message history if the reference no is not found in mstb_dly_msg_in table.