Infiniband Interfaces Do Not Work After Rebooting an Exadata VM - Error: "clib0: P_Key 0xa002 is not found"
(Doc ID 2525080.1)
Last updated on OCTOBER 25, 2020
Applies to:
Oracle VM - Version 3.4.2 and laterLinux x86-64
Symptoms
Error in dmesg when starting interface manually
[235640.710536] clib0: P_Key 0xa002 is not found
[235676.824189] clib1: P_Key 0xa002 is not found
The vm is confiugred with the following 4 Interfaces on Physical Machine in vm.cfg file:
ib_pkeys = [{'pf':'03:00.0','port':'1','pkey':['0x2a00','0xa002',]},{'pf':'03:00.0','port':'2','pkey':['0x2a00','0xa002',]},]
2 Interfaces are working fine on same Virtual Machine with or without reboot and no errors reported for 2 interfaces and issue seen only on other 2 IB interfaces.
Changes
After changing the memory settings, VM InfiniBand interfaces are not up or after bounce VM InfiniBand interfaces are not up