[PCA] Upgrade of Management Node Firmware Caused VM Outage due to Unexpected Mounts on /nfs/shared_storage
(Doc ID 2762072.1)
Last updated on MARCH 21, 2021
Applies to:
Private Cloud Appliance - Version 2.3.1 and laterLinux x86-64
Symptoms
Upgrade of a PCA Management node failed at the point where "umount" of the /nfs/shared_storage failed due to extraneous mounts.
This led to rollback of the upgrade, which caused timeout issues leading to node outage.
From the "pca_upgrader -U -t storage-network" log:
Changes
Upgrading system using "How to upgrade the ILOM service processor firmware on PCA compute and management nodes. (Doc ID 2350974.1)"
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |