E-PIA: Web Error: "Could not load PortalBrowserProps"
(Doc ID 637389.1)
Last updated on APRIL 04, 2025
Applies to:
PeopleSoft Enterprise PT PeopleTools - Version 8.4 and laterInformation in this document applies to any platform.
Information in this document applies to any platform.
SPECIFIC TO: PT8.4x
This document was previously published as Customer Connection Solution 200959450
Symptoms
Running on Solaris 9, CT is trying to connect on PIA, but gets HTTP Error 500.In the log:
# [11/24/04 13:00:31:584 CET] 1245e75 WebGroup I SRVE0180I: [Portal] [/] [Servlet.LOG]: Could not load PortalBrowserProps
[11/24/04 13:00:31:611 CET] 1245e75 WebGroup E SRVE0026E: [Servlet Error]-[]: java.lang.NullPointerException at java.lang.String.<init>(String.javANSWER:404)
It appears that the AppServ domain didn't boot, failing on JSL.
The port used by JSL is 9010
Under Solaris 9, there is a service called IIIM, running on the port 9010.
So the AppServ domain was failing at start-up, but the PIA was finding something on the defined port, obviously the wrong application.
This doens't occur under Solaris 8.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |