Error Received when Saving a Requisition with a Project Chartfield.
(Doc ID 964673.1)
Last updated on MARCH 06, 2023
Applies to:
PeopleSoft Enterprise SCM Purchasing - Version 9 to 9 [Release 9]Information in this document applies to any platform.
Symptoms
When attempting to save a requisition, the following error occurs.
ERROR
-----------------------
SetID not found for name = 'BUSINESS_UNIT' , value = " with record 'PROJECT_ID_VW, Tree". (2,214)
FUNCLIB_FS.EDIT_CHARTFIELD.FieldFormula Name:edit_chartfield PCPC:607 Statement:9
Called from:SCM_PO.Common.Chartfields.OnExecute
Name:CheckChartfields Statement:43
Called form:SCM_PO.Common.ChartFields.OnExecute Name:Validation Statement:413
Called from:REQ_LN_DISTRIB.ACCOUNT.SaveEdit Name:do_validation Statement:61
Called from:REQ_LN_DISTRIB.ACCOUNT.SaveEdit Statement:70
Steps to recreate the issue:
1. Project Costing is not Selected on the Installation Options page.
2. Chartfield Edit = Reject at the PO Business Unit
3. Create a requisition. Use a Project Chartfield without a PC BU on the Distribution. Save.
BUSINESS IMPACT
-----------------------
The issue has the following business impact:
Due to this issue, users cannot save a requisition with a Project Chartfield.
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |