Components Become Unavailable After Reconfig Command
(Doc ID 1203183.1)
Last updated on NOVEMBER 14, 2019
Applies to:
Siebel CRM - Version 8.0.0.8[20430] and laterSiebel Call Center - Version 8.0.0.8 SIA[20430] and later
Information in this document applies to any platform.
***Checked for relevance on 06-Dec-2012***
Symptoms
The below srvrmgr commands are used to change the parameter of a component:
srvrmgr > change parameter <parameter>=<new value> for compdef <compdef name>
srvrmgr > commit reconfig compdef <compdef name>
On Siebel 8.x, after executing the above commands, the component becomes Unavailable after 3-4 minutes. Then, the only workaround is to restart Siebel and Gateway services.
The following errors are displayed in the log files:
SBL-SEC-10007: The password you have entered is not correct. Please enter your password again.
SBL-DAT-00569: The password you have entered is not correct. Please enter your password again.
SBL-OMS-00107: Object manager error: ([0] The password you have entered is not correct. Please enter your password again.(SBL-DAT-00569)
Note the reconfig command works fine with Interactive Components, e.g: SCCObjMgr_enu and EAIObjMgr_enu. These components do not become Unavailable after the changes.
However, most of Batch components become Unavailable after the changes, e.g: WfProcBatchMgr,WfProcMgr, WfRecvMgr.
Cause