[Open UI] - "Applet_ChangeFieldValue" Doesn't retrieve the updated value when Immediate Post change is not set to TRUE (Doc ID 2124825.1)

Last updated on APRIL 07, 2016

Applies to:

Siebel CRM - Version 8.1.1.14.11 [IP2014] and later
Information in this document applies to any platform.

Symptoms

On : 8.1.1.14.11 [IP2014] version, Configuration - General


When using Open UI, the Applet_ChangeFieldValue event in Siebel Browser Scripting doesn't work as HI.

Steps to reproduce:

1. Add the following code in Applet_ChangeFieldValue in browser script:

function Applet_ChangeFieldValue (field, value)
{
alert("the value of field is "+value);
}

2. Set Immediate Post Change as FALSE for the field 'Description'.

3. Compile and Launch the Application.

Navigated to the Applet, and insert a value for the field, select tab and verify the alert message.

Results:

HI --> the field has value=1, if end user insert 2 the event fire value 2, if end user insert 3 the event fire value 3.
OUI --> the field has value=1, if end user insert 2 the event fire value 1, if end user insert 3 the event fire value 1


Cause