Siebel Remote: Endtxnutl failing with error 'SBL-DCK-00110: Cannot find information for node %1'

(Doc ID 2354908.1)

Last updated on JANUARY 31, 2018

Applies to:

Siebel Replication Manager - Version [IP2014] and later
Information in this document applies to any platform.


Siebel Remote / Replication / Anywhere - on version: [IP2014]

When attempting to run endtxnutl, the following error occurs:

SBL-DCK-00110: Cannot find information for node PRD-SRV01@/APP01/SIEBEL/SEA81/SIEBSRVR

The issue can be reproduced at will with the following steps:
1. run utility as - /app01/Siebel/sea81/siebsrvr/bin/endtxnutl  /U SADMIN /P ***** /C PRDHQ81_DSN /D SIEBEL /A PRD-SRV01 /T 24 /O /tmp/endtxnutl.out

The issue has the following business impact:
Due to this issue, TxnProc can not insert dummy parent records in S_DOCK_TXN_LOG table.