Custom WFprocmgr Comp Fails eith SBL-SMI-00121: Internal: SISDecodeRawMessage()
(Doc ID 2471599.1)
Last updated on SEPTEMBER 08, 2023
Applies to:
Siebel CRM - Version 15.6 [IP2015] and laterInformation in this document applies to any platform.
Symptoms
A custom Siebel server component has been created that is a clone of the out of the box WfProcMgr component per requirements.
ERROR MESSAGE:
--------------------------
The error message that occurs with this issue is:
SBL-SMI-00121: Internal: SISDecodeRawMessage() failed
SBL-SMI-00030: Internal: Could not encode a SISNAPI message
STEPS TO REPRODUCE:
---------------------------------
The behaviour occurs as follows:
1. Requests are put into the S_SRM_REQUEST table for the custom component EQXECPWfProcMgr
2. SRProc picks up the request and routes them to SRBroker
3. SRBroker routes them to EQXECPWfProcMgr
4. The EQXECPWfProcMgr starts and runs, performs the workflow but generates this message.
Changes
Cause