Cannot Create New Field In Transient Business Component as TBC Is Exhausted
(Doc ID 2598478.1)
Last updated on OCTOBER 06, 2021
Applies to:
Siebel CRM - Version 15.18 [IP2015] and laterInformation in this document applies to any platform.
Symptoms
Unable to create new Fields in Transient Business Component as BC is exhausted
ERROR:
Field <?> in the TBC mapping array cannot be mapped. Most likely one of the following two things happened in your transient BC configuration.
1) You specified an invalid text length, for example, a length that is greater than 2000. Siebel only supports text length less than 2000.
2) Your TBC has exausted the supported number of columns of certain or all sizes on the tables that TBCs are mapped to. If you have not specified any length for your fields, please try to do so now so that columns of smaller sizes may be utilized. If you have provided text length as best as possible and still see the error, you might want to try to reduce the number of fields on your BC, especially the ones with large sizes.(SBL-DAT-60214)
STEPS
1. Launch Siebel tools
2. Create new Transient Business component using the File menu, and then the New Object menu item.In the New Object Wizards dialog box, choose the Task tab.Choose the Transient BusComp icon, and then click OK.
3. Create 150 Fields with length as 500 in the business component created in step 2
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |