Task Based UI Connector Changes Type Automatically After Reconnecting, Resulting In Error SBL-BPR-00150 (Doc ID 2606480.1)

Last updated on JULY 21, 2020

Applies to:

Siebel CRM - Version 19.5 and later
Information in this document applies to any platform.

Symptoms

On : 19.5 version, Configuration - Dev Env

When a connector within Task Based UI (TBUI) is edited, meaning reconnected to a different step, the type is automatically changed to "Connector" while at first it was "Default".
Since a Decision Point step needs to have a "Default" connector or "Condition" type connectors, a "Connector" type is not working. This throws an error while starting this TBUI process:

SBL-BPR-00150 Error loading branch in step definition '%1': Branch type 'Connector' is invalid on Start, Decision and Interact steps.


STEPS
-----------------------
The issue can be reproduced at will with the following steps in Main workspace after Lock Project:
1. Create a valid Task with at least 1 Decision Point step.
2. Make sure that 1 out-connector is of type "Default" and create at least 1 out-connector of type "Condition"
3. Test Task via GUI (No error)
4. Edit the Task again
5. Create a new step (type doesn't matter)
6. Reconnect the Decision Point out-connector of type "Default" to this new step.
7. Connect the new step to the flow by a new connector (make a valid Task)
8. Test Task via GUI (error)
9. Inspect the out-connector of type "Default"
10. Note that it is changed to type "Connector", throwing the above error.


Cause