SRVRMGR IS CHANGING THE VALUE OF SESSPERSISNCONN IN RUNTIME DESPITE OF ERROR SBL-ADM-05012 (Doc ID 942098.1)

Last updated on DECEMBER 01, 2016

Applies to:

Siebel System Software - Version 8.0 [20405] and later
Information in this document applies to any platform.
***Checked for relevance on 10-DEC-2014***

Goal

The customer would like to understand why SessPerSisnConn parameter can be changed at component level despite of the error SBL-ADM-05012 that says the parameter cannot be changed.

See below what was reported by the customer and reproduced internally:

srvrmgr:app01> change param sesspersisnconn=10 for comp eaiobjmgr_enu

change param sesspersisnconn=10 for comp eaiobjmgr_enu
SBL-ADM-60070: Error reported on server 'Gateway Server' follows:
SBL-ADM-05012: Could not change value of parameter sesspersisnconn to 10
SBL-SCC-00029: Setting parameter "SessPerSisnConn" on level "Component" is not supported.
SBL-ADM-05012: Could not change value of parameter sesspersisnconn to 10
SBL-SCC-00029: Setting parameter "SessPerSisnConn" on level "Component" is not supported.

srvrmgr:app01> list advanced param SessPerSisnConn for comp EAIObjMgr_enu server app01

PA_ALIAS PA_VALUE PA_DATATYPE PA_SCOPE PA_SUBSYSTEM PA_SETLEVEL PA_DISP_SETLEVEL PA PA PA PA PA_NAME
--------------- -------- ----------- --------- ------------ ----------- ------------------- -- -- -- -- -----------------------------------------
SessPerSisnConn 10 Integer Subsystem Interactive Comp level Component level set N Y N Y Number of Sessions per SISNAPI Connection

1 row returned.


The customer was expecting to see PA_SETLEVEL = "Compdef level" instead of "Comp level".