Change on the System Preference "Enable ST Script Engine" may cause error SBL-DAT-00228.
(Doc ID 989719.1)
Last updated on APRIL 04, 2025
Applies to:
Siebel CRM - Version 8.0 [20405] to 8.2.2 SIA[22320] [Release V8]Information in this document applies to any platform.
Symptoms
System Preference "Enable ST Script Engine" controls if the Strong Typing (ST) eScript engine is used or not, and it has to match the code in SRF. If they do not match, dedicated web client may see the error when scripting is about to run. Actual error may vary but one case is "The user ID or password that you entered is incorrect." error upon the login operation. If siebel.log file records following error message, please verify the possible scenarios below.
SBL-DAT-00228: Unable to load the scripting extension language DLL 'sscfjs'
Scripting was enabled in this instance of Siebel, but the DLL which is needed to implement it could not be loaded.
Case 1) After SRF was compiled with "Enable ST Script Engine" = TRUE, this value has been changed to FALSE, or vice versa, without re-compilation of SRF.
Case 2) After "Enable ST Script Engine" is changed on Siebel Tools Client, new SRF is compiled "without" re-login to Siebel Tools Client.
Case 3) Using the same SRF and CFG file, the same error occurs on the server database but not on the local database, or vice versa.
Change Request 10509904 has been filed for this behavior.
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |