Sun StorEdge 351x/33x0 Arrays: Mute Button Held During Reset of Array Will Cause False Battery Failure Messages

(Doc ID 1006414.1)

Last updated on APRIL 15, 2014

Applies to:

Sun Storage 3510 FC Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 3310 Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 3320 SCSI Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 3511 SATA Array - Version Not Applicable to Not Applicable [Release N/A]
All Platforms

Symptoms

False battery failure events can get generated if the mute button on the right front of the RAID or JBOD expansion array is stuck in the depressed position during a reset of the array.

The DRIVE LED patterns will be all amber, then all green, then all off, then random green on. This cycle repeats until the mute button is unstuck.

 

You will see the following pop-up error messages from the firmware menu:

 

You may also reference <Document 1008188.1> Sun Storage 3000 Arrays: Troubleshooting Battery Problems