My Oracle Support Banner

Brocade Silkworm[TM] Switch portPhys State "Mod_Val" (Doc ID 1008351.1)

Last updated on OCTOBER 03, 2022

Applies to:

Brocade 200E Switch - Version All Versions to All Versions [Release All Releases]
All Platforms

Symptoms

 

Some ports in a Brocade Silkworm[TM] 200/E Switch showed portPhys State as "Mod_Val".

Fabric OS:  v5.0.1a
:
:
switchshow:
switchName:     swd77
switchType:     34.0
switchState:    Online  
:
:
Area Port Media Speed State
==============================
  0   0   id    N4   Online    F-Port  21:00:00:e0:8b:91:c7:bf
  1   1   id    N4   Online    F-Port  21:00:00:e0:8b:88:9e:80
  2   2   id    N4   Laser_Flt
  3   3   id    N4   Online    F-Port  21:00:00:e0:8b:87:9c:bf
  4   4   id    N2   Online    F-Port  20:04:00:a0:b8:21:11:5c
  5   5   id    N4   Mod_Val   <----------------???
  6   6   id    N4   Mod_Val   <----------------???
  7   7   id    N4   Mod_Val   <----------------???
  8   8   --    N4   No_Module (No POD License) Disabled
:
:
swd77:admin> portshow 7
portName:
portHealth: No License 
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x4001        PRESENT U_PORT LED
portType:  11.0
portState: 2    Offline 
portPhys:  10   Mod_Val   <--------------------------????
portScn:   0             
port generation number:    0
portId:    010700
portIfId:    43020007
portWwn:   20:07:00:05:1e:02:c9:dc
portWwn of device(s) connected:
        None
Distance:  normal
portSpeed: N4Gbps

Changes

 

Cause