Sun Storage[TM] 3510 FC Array Experiences Unexpected SES Events
(Doc ID 1012828.1)
Last updated on MAY 01, 2023
Applies to:
Sun Storage 3510 FC Array - Version Not Applicable to Not Applicable [Release N/A]All Platforms
Goal
Description
Customers have reported that every 30 seconds as per polling interval, events were getting reported suggesting a bad power supply which can only be cleared by a power cycle of the Sun Storage[TM] 3510 FC Array.
Such events include: false power supply, not available messages, and amber LEDs on drives, controller, front panel and power supply.
Reported cases were with seen with DC power supplies.
Errors from persistent eventlog:
Thu Jun 8 14:33:28 2006 [Primary] Notification SES(C2 I12)Power Supply 1:Power Supply Back On-Line
Thu Jun 8 14:34:25 2006 [Primary] Alert SES(C2 I12)Power Supply 0:Device Not Availabled !
Thu Jun 8 14:34:25 2006 [Primary] Alert SES(C2 I12)Power Supply 1:Device Not Availabled !
Thu Jun 8 14:35:55 2006 [Primary] Notification SES(C2 I12)Power Supply 0:Power Supply Back On-Line
Thu Jun 8 14:35:55 2006 [Primary] Notification SES(C2 I12)Power Supply 1:Power Supply Back On-Line
Also seen:
Thu Jun 8 18:00:44 2006 [3F3f] #5542: SES Device on StorEdge Array SN#<SERIAL_NUMBER> CH2 ID12: ALERT: PS 0 power supply state changed to critical
Thu Jun 8 18:00:44 2006 [3F3f] #5543: SES Device on StorEdge Array SN#<SERIAL_NUMBER> CH2 ID12: ALERT: PS 1 power supply state changed to critical
Thu Jun 8 18:01:42 2006 [3Fdf] #5544: SES Device on StorEdge Array SN#<SERIAL_NUMBER> CH2 ID12: NOTICE: PS 0 power supply is no longer critical
Thu Jun 8 18:01:42 2006 [3Fdf] #5545: SES Device on StorEdge Array SN#<SERIAL_NUMBER> CH2 ID12: NOTICE: PS 1 power supply is no longer critical
In addition, the following amber LEDs were reported:
- Disks 0 and 1
- secondary controller (lower)
- all front panel LEDs except for fan
- either left or right power supply (varies across power cycles).
Name: FC_CHASSIS_BKPLN Description: SE3510 FC Chassis/backplane Part Number: 370-5535 Serial Number: <SERIAL_NUMBER> Revision: 02 Manufacturing Date: Wed Sep 14 09:13:59 2005 Manufacturing Location: Suzhou,China Manufacturer JEDEC ID: 0x0301 FRU Location: FC MIDPLANE SLOT Chassis Serial Number: <SERIAL_NUMBER> FRU Status: Fault
Solution
To view full details, sign in with your My Oracle Support account. |
|