LCMMAIN Fails With Abend 878-14 In A Tapeless VSM Environment (Doc ID 1340805.1)

Last updated on AUGUST 17, 2016

Applies to:

Sun StorageTek Enterprise Library Software (ELS) - Version 7.0 to 7.1 [Release 7.0]
IBM z/OS on System z
This document is relevant only to HSC/VTCS environments that are entirely tapeless; in other words, no RTDs defined.


Symptoms

LCM scratch synchronization job fails every time with 878-14.
Increasing region does not resolve this problem due to the type of 878 abend.
MVCRPT abends with S878-14 abend.

Messages from the LCMMSGS log:

LCM0504I Parameter file processing completed successfully.
LCM0508I VOLDEF file processing completed successfully.
LCM0001I LCM has completed successfully.
IEA995I SYMPTOM DUMP OUTPUT 982
IEA705I ERROR DURING GETMAIN SYS CODE = 878-14
SYSTEM COMPLETION CODE=878 REASON CODE=00000014