L700e Library is installed with LTO2 & LTO4 drives.
After upgrading Library code from 3.15.02 to 3.18.02, mount operations on all LTO4 drive are failing intermittently.
LT02 operations are not affected.

Below FSCs are logged for mount operation on LTO4 drives from ACSLS or directly from L700.

3E0A   ---     ERR_DRV_CMD_TTI_FAILURE,                        -  DRV Command Failed - TTI communication to drive failed.
3E15   ---     ERR_DRV_CONN_STATE_NOT_FUNCTIONAL - DRV Drive Connection State Transition - Drive not functional.


FSC3E0A
FSC3E15

Changes

Code upgrade from 3.15.02 to 3.18.0.

Cause