Hard Disk Incorrect Mapping After Disks Replacement - Celldisk Does Not Drop Before Replacing The Physical Disk
(Doc ID 1468477.1)
Last updated on OCTOBER 04, 2021
Applies to:
Exadata Database Machine X2-2 Hardware - Version All Versions and laterInformation in this document applies to any platform.
After disk replacement, the status is following :-
CellCLI> list lun attributes name,celldisk,status
EXAMPLE :-
0_3 CD_03_gfsdw2cel02 normal
0_4
Symptoms
Normally the devices (12 physical disks ) at OS level use the path /dev/sdX, where the map is
slot# device
----------------------
0 sda
1 sdb
2 sdc
3 sdd
4 sde
5 sdf
6 sdg
7 sdh
8 sdi
9 sdj
10 sdk
11 sdl
Now, when the disks on slot 4 was replaced, it didn't reuse the original letter, so now the mapping is
slot# device
----------------------
0 sda
1 sdb
2 sdc
3 sdd
4 sdac
5 sde
6 sdf
7 sdg
8 sdh
9 sdi
10 sdj
11 sdk
SUNDIAG will show incorrect mapping :-
SUNDIAG
LUN:
------------------
name: 0_4
cellDisk:
deviceName: /dev/sdac <<<< Should be /dev/sde
Cause
To view full details, sign in with your My Oracle Support account. |
|