My Oracle Support Banner

SL8500 - RC: 5014: End of Rail ID testing failed, Can Not Init, cmo_user_init_end_of_rail: Scanner Calibration failed, No target found at Endstop Array (Doc ID 1486401.1)

Last updated on JULY 09, 2022

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

<p >*Symptoms
<span >Briefly describe the symptoms of the problem. Remember to delete any customer specific information

Robot is in Error state.
Robot is offline

The following return codes were logged aggainst the robot:

5014  "The max or min current was requested an excessive amount of times"
          Failed to straighted robot prior to move
          servo mech track event 5014 
5038  "The mechanism is not operational"
          Failed to straighten robot prior to move, track not enabled
5065  "A motor hall error was detected"

 

A robot sent out a series of warning errors like these:

2012-08-19T09:24:12.236,  1.2.0.2.0,      root,      hli0,  move,  39782410,  warn,  3992, "Warning from device", Data=<response sequence="13256102" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>5038</resultCode><resultText><!|CDATA|Failed to straighten robot prior to move, track not enabled; End of Text||></resultText><operationalState>000</operationalState></resultStatus><address>1,2,38,2,1</address></result></response>

2012-08-20T11:25:49.502,  1.2.0.2.0,      root,      hli0,  move,  39853990,  warn,  3992, "Warning from device", Data=<response sequence="13283199" final="true"><command>putCartridge</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>5014</resultCode><resultText><!|CDATA|cmo_user_put: Retry Performed 5611; servo mech track event 5014 at 9162 tachs, 16597 mils||></resultText><operationalState>000</operationalState></resultStatus><address>1,2,35,1,11</address></result></response>

2012-08-20T13:05:40.851,  1.2.0.2.0,      root,      hli0,  move,  39867970,  warn,  3992, "Warning from device", Data=<response sequence="13288395" final="true"><command>fetchCartridge</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>5014</resultCode><resultText><!|CDATA|cmo_user_fetch: Retry Performed 5610; cmo_calibrate failed to find target for address (LRCSR) 1,2,21,1,6 after 1 attempts, cmo_status=5; Failed to straighted robot prior to move, result code=0, mech=0; End of Text||></resultText><operationalState>000</operationalState></resultStatus><address>1,2,21,1,6</address></result></response>

 

Eventually the robot operational state becomes degraded and it requested to be reset:

2012-08-21T05:44:01.717,  1.2.0.2.0,      root,      hli0,  move,  39960040,  error,  3955, "Error from device Code: 514 - Robot needs to be reset", Data=<response sequence="13321536" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5014</resultCode><resultText><!|CDATA|servo mech track event 5014 at 73841 tachs, 133764 mils||></resultText><operationalState>514</operationalState></resultStatus><address>1,2,10,1,0</address></result></response>

2012-08-21T05:44:01.771,  1.2.0.2.0,      root,      hli0,  move,  39960040,  error,  1319, "Robot operation failed Code: 514 - Robot needs to be reset", Data:=<response sequence="13321536" final="true"><command>moveToPosition</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5014</resultCode><resultText><!|CDATA|servo mech track event 5014 at 73841 tachs, 133764 mils||></resultText><operationalState>514</operationalState></resultStatus><address>1,2,10,1,0</address></result></response> volumeLabel=440434~R hliLsm=1

 

Initialization failed and the robot went offline on the SLC:

2012-08-21T14:21:33.694,  1.2.0.2.0,      root,   default,  internal,         0,  error,  3955, "Error from device Code: 512 - Robot can not go operational", Data=<response sequence="13336502" final="true"><command>initialize</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5014</resultCode><resultText><!|CDATA|DIRECTOR End of Rail Init: End of Rail ID testing failed, cannot init, cmo_user_init_end_of_rail: Scanner Calibration failed, No target found at Endstop Array. Possible Scanner failure or a Bad Target or a missing Array cmo_calibrate failed to find target||></resultText><operationalState>512</operationalState></resultStatus><atEndOfRail>false</atEndOfRail></result></response>


2012-08-21T14:21:33.863,  1.0.0.0.0,      root,   default,  internal,         0,  error,  3215, "Robot initialization error - Data: 2012-08-21T14:21:33.856, 1.2.0.2.0,    root, default,    internal,       0, error, 1302, "Failure from robot Code: 512 - Robot can not go operational", Data:=<response sequence="13336502" final="true"><command>initialize</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>5014</resultCode><resultText><!|CDATA|DIRECTOR End of Rail Init: End of Rail ID testing failed, cannot init, cmo_user_init_end_of_rail: Scanner Calibration failed, No target found at Endstop Array. Possible Scanner failure or a Bad Target or a missing Array cmo_calibrate failed to find target||></resultText><operationalState>512</operationalState></resultStatus><atEndOfRail>false</atEndOfRail></result></response>"


Note: A tape in the robot hand may have caused the scanner calibration failure.

Changes

 no known change

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.