Corrupt or Zero Byte MegaCli64 file Can Cause cellcli Output to Show Missing Disks on Exadata Platform
(Doc ID 1490765.1)
Last updated on OCTOBER 29, 2021
Applies to:
Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]Exadata Database Machine X2-2 Qtr Rack - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-8 - Version All Versions to All Versions [Release All Releases]
Oracle Exadata Hardware - Version 11.2.0.1 to 11.2.3.1.1 [Release 11.2]
Exadata Database Machine X2-2 Full Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Exadata storage cell reports ALL disks as not present,yet drives can be seen by using the lsscsi command and cell continues to function.
# cellcli -e "list physicaldisk"
24:0 <SERIAL_NUMBER> not present
24:1 <SERIAL_NUMBER> not present
24:2 <SERIAL_NUMBER> not present
24:3 <SERIAL_NUMBER> not present
24:4 <SERIAL_NUMBER> not present
24:5 <SERIAL_NUMBER> not present
24:6 <SERIAL_NUMBER> not present
24:7 <SERIAL_NUMBER> not present
24:8 <SERIAL_NUMBER> not present
24:9 <SERIAL_NUMBER> not present
24:10 <SERIAL_NUMBER> not present
24:11 <SERIAL_NUMBER> not present
# cellcli -e list physicaldisk where status!=normal
24:0 <SERIAL_NUMBER> not present
24:1 <SERIAL_NUMBER> not present
24:2 <SERIAL_NUMBER> not present
24:3 <SERIAL_NUMBER> not present
24:4 <SERIAL_NUMBER> not present
24:5 <SERIAL_NUMBER> not present
24:6 <SERIAL_NUMBER> not present
24:7 <SERIAL_NUMBER> not present
24:8 <SERIAL_NUMBER> not present
24:9 <SERIAL_NUMBER> not present
24:10 <SERIAL_NUMBER> not present
24:11 <SERIAL_NUMBER> not present
# lsscsi
[0:0:24:0] enclosu LSILOGIC SASX28 A.1 502E -
[0:2:0:0] disk LSI MR9261-8i 2.12 /dev/sda
[0:2:1:0] disk LSI MR9261-8i 2.12 /dev/sdb
[0:2:2:0] disk LSI MR9261-8i 2.12 /dev/sdc
[0:2:3:0] disk LSI MR9261-8i 2.12 /dev/sdd
[0:2:4:0] disk LSI MR9261-8i 2.12 /dev/sde
[0:2:5:0] disk LSI MR9261-8i 2.12 /dev/sdf
[0:2:6:0] disk LSI MR9261-8i 2.12 /dev/sdg
[0:2:7:0] disk LSI MR9261-8i 2.12 /dev/sdh
[0:2:8:0] disk LSI MR9261-8i 2.12 /dev/sdi
[0:2:9:0] disk LSI MR9261-8i 2.12 /dev/sdj
[0:2:10:0] disk LSI MR9261-8i 2.12 /dev/sdk
[0:2:11:0] disk LSI MR9261-8i 2.12 /dev/sdl
In addition when /opt/MegaRAID/MegaCli/MegaCli64 is run it will not produce any output ,neither will sundiag collections show any output from MegaCli64 commands.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |