Fan Column Fault Being Reported Incorrectly On Exadata V2, X2-2, X2-8 Systems on Exadata Software Versions 11.2.3.2.0 and earlier (Doc ID 1536694.1)

Last updated on NOVEMBER 07, 2014

Applies to:

Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-8 - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases]
Linux x86-64

Symptoms

X2-2 & X2-8: Fan failures for non-existent fans on X4270M2 Storage Cells. 

During ILOM boot, the SP runs I2C diagnostics and believes that 2 Fan Modules (FM5 & FM6) are not present which fools it into thinking its an invalid configuration and then produces a fault for non-existent F2 & F3 on FM1 & FM3.

This may result in the host server being shutdown for a fan column fault, or not be able to power it on until the fault is cleared.

 

Changes

 None

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms