Sun Storage Common Array Manager: How to Redistribute Volumes on a Sun Storage 6000/2500/Flexline Array (Doc ID 1568284.1)

Last updated on SEPTEMBER 21, 2015

Applies to:

Sun Storage 2540-M2 Array - Version Not Applicable and later
Sun Storage Flexline 240 Array - Version Not Applicable and later
Sun Storage Flexline 280 Array - Version Not Applicable and later
Sun Storage Flexline 380 Array - Version Not Applicable and later
Sun Storage Common Array Manager (CAM) - Version 6.0 and later
Information in this document applies to any platform.

Goal

This document describes how to redistribute ownership of all volumes on an Sun Storage 6000/2500/Flexline array back to their preferred controller via the Sun Storage Common Array Manager (CAM) software.
This is often done in response to an xx.66.1010 alarm: "The following volume(s) is/are not managed by their preferred controller."

Solution

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms