My Oracle Support Banner

Resolving SB 6000 AC Input Power Issue - PS0 (Power Supply 0), PS1 (Power Supply 1) Are Faulty (Doc ID 1587809.1)

Last updated on OCTOBER 15, 2024

Applies to:

Sun Blade 6000 System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

How to verify there is a possible power issue with your SB 6000 chassis.

In Solaris, use the following command to view fault information.

# fmadm faulty

------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2013-09-17/23:38:51 cdacc5ef-697c-602e-e528-dcdf88d3e20c SPX86-8000-55 Major

Fault class : fault.chassis.env.power.loss

FRU : /CH/PS0
  (Part Number: 300-2259-03)
  (Serial Number: <SERIAL_NUMBER>)

Description : A power supply AC input voltage failure has occurred.

Response : The service-required LED on the affected power supply and
  chassis will be illuminated.

Impact : Server will be powered down when there are insufficient
  operational power supplies.

Action : Please refer to the associated reference document at
  http://www.sun.com/msg/SPX86-8000-55 for the latest service
  procedures and policies regarding this diagnosis.

------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2013-09-17/23:38:52 a51493a2-d81e-6784-e303-8c08c2190a00 SPX86-8000-55 Major

Fault class : fault.chassis.env.power.loss

FRU : /CH/PS1
  (Part Number: 300-2259-03)
  (Serial Number: <SERIAL_NUMBER>)

Description : A power supply AC input voltage failure has occurred.

Response : The service-required LED on the affected power supply and
  chassis will be illuminated.

Impact : Server will be powered down when there are insufficient
  operational power supplies.

Action : Please refer to the associated reference document at
  http://www.sun.com/msg/SPX86-8000-55 for the latest service
  procedures and policies regarding this diagnosis.

From ILOM, use the following command.

-> show -script /X/logs/event/list

689    Tue Sep 17 23:38:52 2013  Fault     Fault     critical
       Fault detected at time = Tue Sep 17 23:38:52 2013. The suspect component:
        /CH/PS1 has fault.chassis.env.power.loss with probability=100. Refer to 
       http://www.sun.com/msg/SPX86-8000-55 for details.
688    Tue Sep 17 23:38:52 2013  Sensor    Log       critical
       Voltage : /CH/PS1/S0/V_IN_ERR : Predictive Failure Asserted
687    Tue Sep 17 23:38:51 2013  Fault     Fault     critical
       Fault detected at time = Tue Sep 17 23:38:51 2013. The suspect component:
        /CH/PS0 has fault.chassis.env.power.loss with probability=100. Refer to 
       http://www.sun.com/msg/SPX86-8000-55 for details.
686    Tue Sep 17 23:38:50 2013  Sensor    Log       critical
       Voltage : /CH/PS0/S1/V_IN_ERR : Predictive Failure Asserted

 

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
 # fmadm faulty
Changes
Cause
Solution


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.