After Inadvertent Flash Card Removal, 2 PCI Slots And Flash Card No Longer Visible

(Doc ID 1624376.1)

Last updated on SEPTEMBER 19, 2017

Applies to:

Fujitsu M10-4 - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-1 - Version All Versions to All Versions [Release All Releases]
Fujitsu M10-4S - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)

Symptoms

Fujitsu fault codes:

12BB0000, 12BB0001, 01b90006, 05050105

Showhardconf
       PCI#0 Name_Property:network;
           + Vendor-ID:8086; Device-ID:10fb;
           + Subsystem_Vendor-ID:108e; Subsystem-ID:7b11;
           + Model:X1109a-z/1109a-z;
       PCI#2 Name_Property:SUNW,qlc;
           + Vendor-ID:1077; Device-ID:2532;
           + Subsystem_Vendor-ID:1077; Subsystem-ID:0171;
           + Model:QLE2562 ;
       PCI#3 Name_Property:network;
           + Vendor-ID:8086; Device-ID:10fb;
           + Subsystem_Vendor-ID:108e; Subsystem-ID:7b11;
           + Model:X1109a-z/1109a-z;
       PCI#4 Name_Property:network;
           + Vendor-ID:8086; Device-ID:10fb;
           + Subsystem_Vendor-ID:108e; Subsystem-ID:7b11;
           + Model:X1109a-z/1109a-z;
       PCI#8 Name_Property:SUNW,qlc;
           + Vendor-ID:1077; Device-ID:2532;
           + Subsystem_Vendor-ID:1077; Subsystem-ID:0171;
           + Model:QLE2562 ;
       PCI#10 Name_Property:pciex1000,7e;
           + Vendor-ID:1000; Device-ID:007e;
           + Subsystem_Vendor-ID:108e; Subsystem-ID:0581;
           + Model:;

 

Missing PCI #6.

showlogs_error_-vr.out:

Date: Feb 12 20:30:24 UTC 2014
    Code: 40000000-006b020000ff0000ff-12bb00000000000000000000
    Status: Warning                Occurred: Feb 12 20:30:21.106 UTC 2014
    FRU: /BB#0/CMUU
    Msg: PCI access error
    Diagnostic Code:
        00000100 00000000 0000
        00000000 00000000 0000
        00000000 00000000 0000
        00000000 00000000 00000000 00000000
        00000000 00000000 0000
Date: Feb 12 20:11:26 UTC 2014
    Code: 40000000-006b020000ff0000ff-12bb00000000000000000000
    Status: Warning                Occurred: Feb 12 20:11:26.623 UTC 2014
    FRU: /BB#0/CMUU
    Msg: PCI access error
    Diagnostic Code:
        00000100 00000000 0000
        00000000 00000000 0000
        00000000 00000000 0000
        00000000 00000000 00000000 00000000
        00000000 00000000 0000
Date: Feb 12 20:09:41 UTC 2014
    Code: 40000000-00ffff0000ff0000ff-01b900060000000000000000
    Status: Warning                Occurred: Feb 12 20:09:41.055 UTC 2014
    FRU: /UNSPECIFIED
    Msg: XSCF command: System status change (OS panic) (PPARID#00, path: 00)
    Diagnostic Code:
        00000000 00000000 0000
        00000000 00000000 0000
        00000000 00000000 0000
        00000000 00000000 00000000 00000000
        00000000 00000000 0000
Date: Feb 12 20:06:51 UTC 2014
    Code: 40002108-006b020000ff0000ff-05050105002003400087b000
    Status: Warning                Occurred: Feb 12 20:06:42.058 UTC 2014
    FRU: /BB#0/CMUU
    Msg: CPU PCIe host bridge internal serious error
    Diagnostic Code:
        00000100 00000000 0000
        00000000 00000000 0000
        00000000 00000000 0000
        01000000 00000000 0005102b 0340087b
        00000000 00000000 0000

 

Changes

The PCI Flash Card: 7026993 [C] Flash Accelerator F40 400GB Solid State Memory was inadvertently removed.

After removal w/o invoking cfgadm unconfigure -c the Card was reinserted and XSCF> poweroff -yp 0 and then poweron but system no longer recognized card at the Hardware/XSCF level.

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a