BBU BATTERIES DON'T FULLY CHARGE UP TO 100% OF AVAILABLE CAPACITY (Doc ID 1669359.1)

Last updated on MAY 09, 2014

Applies to:

Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 RAID controller firmware version 12.12.0-178

The battery will run charge/learn cycles approximately every two days .

The battery charge may not show 100% despite a new battery being fitted.

 

An example below after using the command :

Events log also shows charge cycles are short and more frequent compared to previous firmware versions.

seqNum: 0x00001625
Time: Sun Feb 23 04:48:39 2014

Code: 0x00000093
Class: 0
Locale: 0x08
Event Description: Battery started charging
Event Data:
===========
None


seqNum: 0x00001626
Time: Sun Feb 23 04:52:59 2014

Code: 0x000000f2
Class: 0
Locale: 0x08
Event Description: Battery charge complete
Event Data:

seqNum: 0x00001627
Time: Mon Mar  3 12:51:59 2014

Code: 0x00000093
Class: 0
Locale: 0x08
Event Description: Battery started charging
Event Data:
===========
None


seqNum: 0x00001628
Time: Mon Mar  3 12:56:19 2014

Code: 0x000000f2
Class: 0
Locale: 0x08
Event Description: Battery charge complete

 

Changes

 RAID controller firmware 12.12.0-178

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms