SAM-QFS - Drives Set to DOWN State After samd stop/start With Errors "query drive response status:STATUS_COMMUNICATION_FAILED" (Doc ID 1679045.1)

Last updated on OCTOBER 14, 2016

Applies to:

Oracle Hierarchical Storage Manager (HSM) and StorageTek QFS Software - Version 3.5 to 6.1 [Release 3.0 to 6.0]
Information in this document applies to any platform.

Symptoms

Issues with tape drives led customer to restart ACSLS and the library.

All tape drives are marked to a 'down' state, after running 'samd stop' and 'samd start'.

STATUS_COMMUNICATION_FAILED errors logged in system messages file. This was preceded by a "getrpcbyname failed" error.

Prior to this, the only problem was with drive 601:
-------


There is only one SSI process ( ssi_so ) running but rpcinfo shows three SSI program numbers that cannot be deleted by 'rpcinfo -d'.
( These might be preventing the robotics daemons to restart successfully. )

Changes

Rebooted the library and cycled the ACSLS software

Cause