My Oracle Support Banner

"Write Cache Active" Becomes False After Firmware Upgrade to 7.xx (Doc ID 1906072.1)

Last updated on NOVEMBER 10, 2020

Applies to:

Sun Storage 6180 Array - Version All Versions and later
Sun Storage 6780 Array - Version All Versions and later
Sun Storage 6580 Array - Version All Versions and later
Sun Storage 6540 Array - Version All Versions and later
Sun Storage 6140 Array - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Write Cache gets disabled for all volumes when the array controller firmware is upgraded from any 07.xx firmware revision to 07.60.18.10 or later revisions up to 07.60.56.10.
Note that this symptom can also be seen while upgrading from 06.xx to 07.xx, because 06.xx to 07.xx upgrade utility takes to 07.15.xx.xx firmware first and then to later revisions.

This issue can be verified from file "storageArrayProfile.txt" under CAM supportdata collected after the firmware upgrade. Refer to <Document 1002514.1> Collecting Sun Storage Common Array Manager Support Data for Arrays for steps to collect array supportdata.

You may also refer to <Document 1674848.1> Sun Storage 2500, 2500-M2, and 6000 Arrays: Performance is Slow on an Apparently Optimal Array for additional steps to verify write cache status.

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution
References