Symptoms

This Solaris 9 SF V440 server1 has two native Emulex LP10000 FC HBAs (non-Oracle FC HBA, using third party driver lpfc)
two ports connected to the SAN to access an EMC storage array, emc powerpath used as multipathing software, LUNs under vxvm control.

There are no SAN packages or patches installed, expected as lpfc is a third party driver.


We can see the EMC disks under c3 and c4 controller:

bash-3.2$ more format.out
Searching for disks...done

  4. c3t30d1
  /pci@1e,600000/lpfc@2/sd@1e,1
...
  11. c3t30d8
  /pci@1e,600000/lpfc@2/sd@1e,8

  12. c4t31d1
  /pci@1e,600000/lpfc@3/sd@1f,1
...
  19. c4t31d8
  /pci@1e,600000/lpfc@3/sd@1f,8

  20. emcpower0a
  /pseudo/emcp@0
...
  29. emcpower297a
  /pseudo/emcp@297

 

The two third party FC HBAs LP10000

bash-3.2$ more prtdiag-v.out

pci 33 PCI0 lpfc-pci10df,fa00 (scsi) LP10000
  okay /pci@1e,600000/lpfc@2
pci 33 PCI0 lpfc-pci10df,fa00 (scsi) LP10000
  okay /pci@1e,600000/lpfc@2,1

pci 33 PCI1 lpfc-pci10df,fa00 (scsi) LP10000
  okay /pci@1e,600000/lpfc@3
pci 33 PCI1 lpfc-pci10df,fa00 (scsi) LP10000
  okay /pci@1e,600000/lpfc@3,1

 

On the messages we can see errors from the EMC storage on both FC HBA ports (/pci@1e,600000/lpfc@2 and /pci@1e,600000/lpfc@3 ) that cause the vxfs file systems to fail:


Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 107247376 Error Block: 107247376
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7514D008Q
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 117733136 Error Block: 117733136
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,8 (sd2459):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7514D008Q
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,6 (sd2457):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0
Aug 22 05:00:23 server1 Error for Command: write Error Level: Fatal
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,6 (sd2457):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 117733136 Error Block: 117733136
Aug 22 05:00:23 server1 Error for Command: write Error Level: Fatal
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7514D008Q
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 65808 Error Block: 65808
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7512D008Q
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,6 (sd2457):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 Error for Command: write Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,8 (sd2459):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,6 (sd2457):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 65808 Error Block: 65808
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 Error for Command: write Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 109344528 Error Block: 109344528
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7512D008Q
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7514D008Q
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0
Aug 22 05:00:24 server1 vxio: [ID 771159 kern.warning] WARNING: VxVM vxio V-5-0-2 Subdisk EMC375L0127E-01 block 16: Uncorrectable write error
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@3/sd@1f,8 (sd2459):
Aug 22 05:00:24 server1 vxfs: [ID 702911 kern.warning] WARNING: msgcnt 13 mesg 039: V-2-39: vx_writesuper - /dev/vx/dsk/PSSAPAUZ44501/data_app file system super-block write error
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.warning] WARNING: /pci@1e,600000/lpfc@2/sd@1e,8 (sd2204):
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:24 server1 vxfs: [ID 702911 kern.warning] WARNING: msgcnt 14 mesg 031: V-2-31: vx_disable - /dev/vx/dsk/PSSAPAUZ44501/data_app file system disabled
Aug 22 05:00:23 server1 Error for Command: write(10) Error Level: Fatal
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 109344528 Error Block: 109344528
Aug 22 05:00:24 server1 vxio: [ID 771159 kern.warning] WARNING: VxVM vxio V-5-0-2 Subdisk EMC375L0128E-04 block 16: Uncorrectable write error
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Requested Block: 107247376 Error Block: 107247376
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7514D008Q
Aug 22 05:00:24 server1 vxfs: [ID 702911 kern.warning] WARNING: msgcnt 15 mesg 039: V-2-39: vx_writesuper - /dev/vx/dsk/PSSAPAUZ44501/var_app file system super-block write error
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Vendor: EMC Serial Number: 7514D008Q
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:24 server1 vxfs: [ID 702911 kern.warning] WARNING: msgcnt 16 mesg 031: V-2-31: vx_disable - /dev/vx/dsk/PSSAPAUZ44501/var_app file system disabled
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] Sense Key: Not Ready
Aug 22 05:00:23 server1 scsi: [ID 107833 kern.notice] ASC: 0x4 (), ASCQ: 0x3, FRU: 0x0

 