Symptoms

cellnode1#ibstatus command shows that the INIT state:

Infiniband device 'mlx4_0' port 2 status:
default gid: fe80:0000:0000:0000:0010:e000:0133:14ff
base lid: 0x29
sm lid: 0x22
state: 2: INIT<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< This port does not see the SM (Subnet Master)
phys state: 5: LinkUp<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Cable is connected and there is a link
rate: 40 Gb/sec (4X QDR)
link_layer: IB

Cause