ibstatus output shows state:init
(Doc ID 1929447.1)
Last updated on JULY 01, 2021
Applies to:
Exadata X3-2 Quarter Rack - Version All Versions and laterInformation in this document applies to any platform.
Symptoms
cellnode1#ibstatus command shows that the INIT state:
Infiniband device 'mlx4_0' port 2 status:
default gid: fe80:0000:0000:0000:0010:e000:0133:14ff
base lid: 0x29
sm lid: 0x22
state: 2: INIT<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< This port does not see the SM (Subnet Master)
phys state: 5: LinkUp<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Cable is connected and there is a link
rate: 40 Gb/sec (4X QDR)
link_layer: IB
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |