My Oracle Support Banner

Sun Storage 2510 Array: Controller Encountered a Host Board Fault (Doc ID 1991531.1)

Last updated on SEPTEMBER 11, 2018

Applies to:

Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

 In the Sun Storage 2510 Array , when a controller encounters host board fault the array reports following alarm.

 

Alarm ID   : alarm331
Description: Controller {0} encountered a host board fault.
Severity   : Critical
Element    : null
GridCode   : 73.66.1105
Date       : 2015-03-10 08:40:14

  

Tray.85.Controller.A
     Status:                        Degraded
     Current configuration
        Firmware version:
           Appware version:         07.35.10.10
           Bootware version:        07.35.10.10
        NVSRAM version:             N1532-735843-002
     Board ID:                      1532
     Replacment part number:        375-3518-03
     Product ID:                    LCSM100_I
     Product revision:              0735
     Serial number:                .......
     Date of manufacture:           Sat May 17 08:00:00 GMT+08:00 2008
     Data Cache Present (MB):       310
     Data Cache Used (MB):          0
     Processor Cache Present (MB):  202
     Date/Time:                     Wed Jan 07 09:19:08 GMT+08:00 2015

  

 

Date/Time: Wed Jan 07 07:21:05 GMT+08:00 2015
Sequence number: 13676
Event type: 180A
Event category: Failure
Priority: Critical
Description: Failed iSCSI I/O host card
Event specific codes: 0/0/0
Component type: HostBoard
Component location: Host Board
Logged by: Controller in slot A

Date/Time: Wed Jan 07 07:21:06 GMT+08:00 2015
Sequence number: 13677
Event type: 1815
Event category: Notification
Priority: Informational
Description: iSCSI carrier lost
Event specific codes: 0/0/0
Component type: Unknown
Component location: UNDEFINED
Logged by: Controller in slot A

Date/Time: Wed Jan 07 07:21:14 GMT+08:00 2015
Sequence number: 13679
Event type: 1814
Event category: Notification
Priority: Informational
Description: iSCSI carrier detected
Event specific codes: 0/0/0
Component type: Unknown
Component location: UNDEFINED
Logged by: Controller in slot A

Date/Time: Wed Jan 07 07:21:20 GMT+08:00 2015
Sequence number: 13681
Event type: 180F
Event category: Notification
Priority: Informational
Description: iSCSI Interface restarted
Event specific codes: 0/0/0
Component type: Unknown
Component location: UNDEFINED
Logged by: Controller in slot A

 


 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Cause
Solution
References