Symptoms

List the changes in 1.52.106(T10000A)  and 1.52.206 (T10000B) microcode.

CR Number FSC Synopsis
21187054 31F4 Fixes ALP error FSC 31F4. Replaces special build RA52.203 code.
21842881 292A Fix for a bug seen with T10KA FC drives with 4G HW attached to 8G HBA’s. Replaces special build RC52.103 code.
22089840 329D Fix for 329D SNO seen in ALP mode.
21443443 3780 Fix for 3780 SNO - Seen on T10k-B ALP tapes.
21614042 3B02 Fix for 3B02 SNO - Customer has T10KB – ALP - VTV's they were unable to read.
22167813 407B Fix for 407B SNO’s seen on T10KB RTD’s where VSM refused to read tapes that had invalid MIR status flags.
22201277 NONE RFE where this code will now provide the TTI version in the VOP code version tab display.
20721833 349C Fix for 349C retry errors were reported as a Perm Error by SDP2/VOP.
22673432 48CE Fix for 48CE. A BSF command over a just written TMK yields FSC 48CE (Crash EOD).
21890870 6025 Fix for 6025 SNO. Replaces RB152.103. W/ OKM Encryption.