15 Minute Integrated Measurements Marked as Incomplete (Doc ID 2136613.1)

Last updated on MAY 17, 2016

Applies to:

Oracle Communications EAGLE (Hardware) - Version EAGLE 44.0.4 and later
Information in this document applies to any platform.

Symptoms

Since the migration from the measurement platform (MCP cards) to the integrated measurement (OAM cards), the report files .csv have the "status" parameter to "I" which means incomplete.
This is not the case on the mated Eagle which is still working with the measurement platform (MCP cards)
As a result, the statistics platform of the customer which is processing the report files is discarding the files having the status as "I"

Cause