Brocade Non-Director Switches Running FOS 7.3.1 Reboots Due To Out Of Memory (OOM) Condition (Doc ID 2188071.1)

Last updated on OCTOBER 05, 2016

Applies to:

Brocade 5100 Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

The Switch will reboot. Events of the following nature will be reported in the fabric log on the switch:

2016/07/30-21:00:56, [HAM-1011], 3412, FFDC | CHASSIS, CRITICAL, Brocade5100, haReboot is automatically triggered for warm recovery from OOM.
2016/07/30-21:00:57, [RAS-1001], 3413, CHASSIS, INFO, Brocade5100, First failure data capture (FFDC) event occurred.
2016/07/30-21:01:05, [RAS-1001], 3414, CHASSIS, INFO, Brocade5100, First failure data capture (FFDC) event occurred.
2016/07/30-21:01:20, [FSSM-1002], 3415, CHASSIS, INFO, Brocade5100, HA State is in sync.
2016/07/30-21:01:46, [RAS-1007], 3416, CHASSIS, INFO, Brocade5100, System is about to reload.
2016/07/30-21:02:35, [HAM-1004], 3417, CHASSIS, INFO, Brocade5100, Processor rebooted - reboot.

This issue has only been reported in Release: FOS7.3.1

Cause