Oracle HSM: 'Read-only file system' Errors When Staging and Archiving to Tape

(Doc ID 2357906.1)

Last updated on FEBRUARY 26, 2018

Applies to:

Oracle Hierarchical Storage Manager (HSM) and StorageTek QFS Software - Version 5.0 and later
Information in this document applies to any platform.

Symptoms

Staging any file results in the file copy becoming 'damaged'. Archiving does not work either. Both the archiver and stager report a 'Read-only filesystem' error in their trace logs.

You are able to read and write to the filesystem and the tapes are NOT set to readonly.

Staging causes an error on the copy:

 

Changes

 No recent changes. However, the filesystem is not frequently used and the retension trigger was set only a few weeks ago. There are 2 other filesystems similarly created that are NOT experiencing any problems.