9840D - FSC 36B2, Drive Has Exceeded the Track Correction Threshold on Simultaneous Tracks

(Doc ID 2361899.1)

Last updated on FEBRUARY 16, 2018

Applies to:

Sun StorageTek 9840D Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.
Type: 9840D Rev: 1.47.702

Symptoms

Customer reports:

21.05.22 ISZ1 IS S4003 ¬SLS6684I RTD VSBAABAA on VTSS VSBA Returned ECAM error CC=97 RC=137
21.05.22 ISZ1 IS S4003 ¬SLS6625E RTD VSBAABAA reported Read data CHK: 0840002300000020000000000000000000000000000000000000000000000000
21.05.22 ISZ1 IS S4003 ¬SLS6605I Initiating swap of MVC VB6988 from RTD VSBAABAA
23:35:39.92 IS S4003 00000000 ¬SLS6788I Invalid MIR reported for MVC WSV033 on RTD VSBAABAA
23:50:14.96 IS S4003 00000000 ¬SLS6788I Invalid MIR reported for MVC VB0369 on RTD VSBAABAA

Multiple volsers have unreadable MIR's

FSC: 36B2 DS_FSC_MIR_UNREADABLE

FSC: 3FC8 PRS_FSC_RTR_PRE_BLK_APP_ERR

These errors have occurred on multiple tape cartridges.

Drive has exceeded the track correction threshold on simultaneous tracks. Replace the drive only if it is also taking MIR write failures or any write perm error.