My Oracle Support Banner

SL150 - Message - "Error : Firefox Can Not Establish a Connection to Server" Seen In The Library Console While Initiating Firmware Upgrade (Doc ID 2368259.1)

Last updated on NOVEMBER 22, 2022

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

The proposed fix to this issue was to upgrade the firmware from the current build of 0260 to 0320. But the system crashes with the same errors as above while initiating the firmware upgrade. This happens at the upload stage. Also attempted to upgrade using version 0300. It also fails with the same error.

Symptoms

Firmware upgrade fails as the web console crash.

Issue with a repeated interface and login message where the Console would become unresponsive/unavailable with the message : error:Unable to Connect. Firefox can't establish a connection to server 127.x.x.x on the op panel of the SL150

The web interface has "Site can't be reached" error.

Tried the same with latest versions of all the browsers IE , Firefox and Chrome but the error is same.

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.