ACSLS - Start Up Failure After Initial HW Configuration, "ACSLS database contains no CAPs"
(Doc ID 2374378.1)
Last updated on JULY 11, 2022
Applies to:
Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 8.0 to 8.5.1 [Release 8.0]Sun StorageTek SL8500 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
ACSLS is not starting after initial configuration of a library.
acsss_event.log shows:
Other symptoms:
acsss_config (option 8) does not show any CAP problem during configuration. The CAPs do show up in acsss_config.log but there is no CAP record in the captable that is associated with the ACS.
CAPs are reported in SLConsole but are not available to ACSLS.
Changes
Newly configured library