LUN not seen/online because PLOGI failed after changing FC Switch ports causing new D_ID to be detected.
Last updated on APRIL 06, 2018
Applies to:
Solaris Operating System - Version 8.0 to 11.3 [Release 8.0 to 11.0]Solaris x64/x86 Operating System - Version 8 6/00 U1 to 11.3 [Release 8.0 to 11.0]
Information in this document applies to any platform.
Symptoms
HOST TYPE : SPARC Enterprise T5120
HOST OS : Solaris 10 1/13 s10s_u11wos_24a SPARC
NON-Oracle Brocade FC Switches
NON-Oracle NetApp storage Array
NON-Oracle Hitachi storage Array
Oracle Multipathing Software (MPXIO)
Oracle 4Gb Dual Port Qlogic FC HBA card SG-XPCIE2FC-QF4/375-3356/QLE2462
Issue
- seeing PLOGI failed type messages
fctl: [ID 517869 kern.warning] WARNING: fp(3)::PLOGI to c1601 failed. state=e reason=5.
fp: [ID 517869 kern.info] NOTICE: fp(3): PLOGI to c1601 failed state=Packet Transport error, reason=No Connection
PLOGI to D_ID=0xc1601 failed: State:Packet Transport error, Reason:No Connection. Giving up
Changes
Issue occurred after recabling targets and new D_ID detect by Solaris
example
fctl: [ID 517869 kern.warning] WARNING: fp(3)::N_x Port with D_ID=c0701, PWWN=201000a0985e73ba disappeared from fabric
fctl: [ID 517869 kern.warning] WARNING: fp(3)::N_x Port with D_ID=13701, PWWN=201000a0985e73ba reappeared in fabric
fctl: [ID 517869 kern.warning] WARNING: fp(3)::N_x Port with D_ID=c1601, PWWN=201300a0985e73ba disappeared from fabric
fctl: [ID 517869 kern.warning] WARNING: fp(3)::N_x Port with D_ID=12601, PWWN=201300a0985e73ba reappeared in fabric
Cause