Infiniband Switch Power Supply P/N 7351491 requires firmware 2.2.9-3 or higher (Doc ID 2407511.1)

Last updated on JUNE 05, 2018

Applies to:

Sun Datacenter InfiniBand Switch 36 - Version All Versions to All Versions [Release All Releases]
Sun Network QDR InfiniBand Gateway Switch - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

1. ibswitches returns "BOOT IN PROGRESS"

# ibswitches returns:
Switch : 0x0010e0dc1011a0a0 ports 36 "BOOT IN PROGRESS" enhanced port 0 lid 0 lmc 0
Switch : 0x0010e035b6c1a0a0 ports 36 "SUN DCS 36P QDR ibb01 10.10.10.2" enhanced port 0 lid 1 lmc 0
Switch : 0x0010e06517d4a0a0 ports 36 "SUN DCS 36P QDR iba01 10.10.10.3" enhanced port 0 lid 3 lmc 0

Note: During boot of an IB switch (running firmware 2.2.4 or higher), the BOOT IN PROGRESS message is valid and expected, but if it is sticky long (more than 5 minute) after the reboot, then there is something wrong.


2. showpsufru can't identify the Power Supplies in the switch that can't identify the hostname in the ibswitches command and then segfaults

# showpsufru 0
Sun_SpecPartNo :
UNIX_Timestamp32 : Wed Dec 31 19:00:00 1969
Sun_Part_Number :
Sun_Serial_No :
Vendor_ID_Code : 0000
Initial_HW_Dash_Level :
PSU_Voltage 1 : 0x0000 (0)
PSU_Current 1 : 0x0000 (0)
PSU_Voltage 2 : 0x0000 (0)
PSU_Current 2 : 0x0000 (0)
Sun_Hazard_Class_Code :

IPMI_Board_Manufacturer :
IPMI_Board_Product_Name : ▒▒
Segmentation fault

[root@ppplx2sw-ibc01 tmp]# showpsufru 1
Sun_SpecPartNo :
UNIX_Timestamp32 : Wed Dec 31 19:00:00 1969
Sun_Part_Number :
Sun_Serial_No :
Vendor_ID_Code : 0000
Initial_HW_Dash_Level :
PSU_Voltage 1 : 0x0000 (0)
PSU_Current 1 : 0x0000 (0)
PSU_Voltage 2 : 0x0000 (0)
PSU_Current 2 : 0x0000 (0)
Sun_Hazard_Class_Code :

IPMI_Board_Manufacturer :
IPMI_Board_Product_Name : ▒▒
Segmentation fault

3. Environment daemon can't start

# service --status-all
acpid (pid 2458) is running...
auditd (pid 2325) is running...
autodis_mon (pid 3090) is running...
.
.
Environment-daemon dead but pid file exists

 

Also possibly:

Starting Environment Daemon test:
WARNING Environment daemon killed
Environment Daemon test returned 1 faults

 

4. Events in the event log:

3540 Wed May 30 15:08:37 2018 Sensor Log minor
OEM : /SYS/MB/BOOT_I4A : State Asserted
3539 Wed May 30 15:06:36 2018 Sensor Log minor
OEM : /SYS/MB/BOOT_I4A : State Deasserted
3538 Wed May 30 15:03:56 2018 Sensor Log minor
OEM : /SYS/MB/BOOT_I4A : State Asserted

 

5. In /var/log/messages, the envd segfault:

May 30 15:06:06 ibs01 kernel: envd[8045]: segfault at 0 ip b7589cef sp bfed9a34 error 4 in libc-2.12.so[b7510000+191000]
May 30 15:06:29 ibs01 envd[8107]: Environment daemon 2.2.7-1 starting
May 30 15:06:29 ibs01 envd[8107]: Fan 0 not present
May 30 15:06:29 ibs01 envd[8107]: Fan 4 not present
May 30 15:06:29 ibs01 envd[8107]: Connector 3A present
May 30 15:06:30 ibs01 envd[8107]: Connector 4A present
May 30 15:06:30 ibs01 envd[8107]: Connector 5A present
May 30 15:06:31 ibs01 envd[8107]: Connector 6A present
May 30 15:06:31 ibs01 envd[8107]: Connector 7A present
May 30 15:06:31 ibs01 envd[8107]: Connector 8A present
May 30 15:06:32 ibs01 envd[8107]: Connector 9A present
May 30 15:06:32 ibs01 envd[8107]: Connector 10A present
May 30 15:06:33 ibs01 envd[8107]: Connector 3B present
May 30 15:06:33 ibs01 envd[8107]: Connector 4B present
May 30 15:06:33 ibs01 envd[8107]: Connector 5B present
May 30 15:06:34 ibs01 envd[8107]: Connector 6B present
May 30 15:06:34 ibs01 envd[8107]: Connector 7B present
May 30 15:06:35 ibs01 envd[8107]: Connector 8B present
May 30 15:06:35 ibs01 envd[8107]: Connector 9B present
May 30 15:06:35 ibs01 envd[8107]: Connector 10B present
May 30 15:06:37 ibs01 kernel: envd[8107]: segfault at 0 ip b7638cef sp bff0ffa4 error 4 in libc-2.12.so[b75bf000+191000]
May 30 15:07:00 ibs01 envd[8360]: Environment daemon 2.2.7-1 starting
May 30 15:07:01 ibs01 envd[8360]: Fan 0 not present
May 30 15:07:01 ibs01 envd[8360]: Fan 4 not present
May 30 15:07:01 ibs01 envd[8360]: Connector 3A present
May 30 15:07:01 ibs01 envd[8360]: Connector 4A present
May 30 15:07:01 ibs01 envd[8360]: Connector 5A present
May 30 15:07:02 ibs01 envd[8360]: Connector 6A present
May 30 15:07:02 ibs01 envd[8360]: Connector 7A present
May 30 15:07:03 ibs01 envd[8360]: Connector 8A present
May 30 15:07:03 ibs01 envd[8360]: Connector 9A present
May 30 15:07:03 ibs01 envd[8360]: Connector 10A present
May 30 15:07:04 ibs01 envd[8360]: Connector 3B present
May 30 15:07:04 ibs01 envd[8360]: Connector 4B present
May 30 15:07:05 ibs01 envd[8360]: Connector 5B present
May 30 15:07:05 ibs01 envd[8360]: Connector 6B present
May 30 15:07:05 ibs01 envd[8360]: Connector 7B present
May 30 15:07:06 ibs01 envd[8360]: Connector 8B present
May 30 15:07:06 ibs01 envd[8360]: Connector 9B present
May 30 15:07:06 ibs01 envd[8360]: Connector 10B present

Changes

 Introduction of Power Supply P/N 7351491 used in Infiniband Switches

Cause