SL3000 - Power Supply Rail-BDM-AC2 Warn, Error 1321 "Failure From Power Supply
(Doc ID 2444215.1)
Last updated on JULY 25, 2022
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform.
Symptoms
PSU faulty
40229 2018-09-05T10:41:50.076 1.0.0.1.3 root default queryLibrary 260701 trace 3816 "Device status warning", status=warn device=powerSupply
40230 2018-09-05T10:41:50.090 1.0.0.1.3 root default queryLibrary 260701 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
40231 2018-09-05T10:41:50.098 1.0.0.1.3 root default queryLibrary 260701 trace 3816 "Device status warning", status=warn device=powerSupply
40297 2018-09-05T10:41:52.905 1.0.0.1.3 root default queryLibrary 262501 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
40298 2018-09-05T10:41:52.913 1.0.0.1.3 root default queryLibrary 262501 trace 3816 "Device status warning", status=warn device=powerSupply
40299 2018-09-05T10:41:52.931 1.0.0.1.3 root default queryLibrary 262501 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
40300 2018-09-05T10:41:52.939 1.0.0.1.3 root default queryLibrary 262501 trace 3816 "Device status warning", status=warn device=powerSupply
40489 2018-09-05T10:43:41.625 1.0.0.1.3 root default queryTable 271101 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
40490 2018-09-05T10:43:41.634 1.0.0.1.3 root default queryTable 271101 trace 3816 "Device status warning", status=warn device=powerSupply
47688 2018-09-06T10:21:30.213 1.0.0.1.3 root default queryLibrary 298701 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
47689 2018-09-06T10:21:30.220 1.0.0.1.3 root default queryLibrary 298701 trace 3816 "Device status warning", status=warn device=powerSupply
47690 2018-09-06T10:21:30.236 1.0.0.1.3 root default queryLibrary 298701 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
47691 2018-09-06T10:21:30.243 1.0.0.1.3 root default queryLibrary 298701 trace 3816 "Device status warning", status=warn device=powerSupply
47758 2018-09-06T10:21:33.133 1.0.0.1.3 root default queryLibrary 300501 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
47759 2018-09-06T10:21:33.141 1.0.0.1.3 root default queryLibrary 300501 trace 3816 "Device status warning", status=warn device=powerSupply
47760 2018-09-06T10:21:33.159 1.0.0.1.3 root default queryLibrary 300501 error 1321 "Failure from power supply - Address: 1,0,0,1,3 - Status: (PowerFail: true)(acOk: true)(dcPowerOk: true)(present: true)"
47761 2018-09-06T10:21:33.167 1.0.0.1.3 root default queryLibrary 300501 trace 3816 "Device status warning", status=warn device=powerSupply
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |