Symptoms

The server crashed due to Critical Voltage Issues on Motherboard and the server fails to power on.

 

 

Event list will show VDD errors typically on a single sensor, though different machines can have different VDD sensors go off:

+1V2_VDD
-> show -script /X/logs/event/list
      Critical voltage value : host is being powered off
556    Wed Sep  5 12:15:27 2018  Chassis   Log       critical     <====== SERVER CRASHED, POWERED OFF
      Critical voltage value : host is being powered off
549    Wed Sep  5 12:07:52 2018  IPMI      Log       critical
      ID =  a00 : 09/05/2018 : 12:07:52 : Voltage : /MB/V_+1V2_VDD : Lower Non-recoverable going low  : reading 0.72 <= threshold 1.08 Volts   <====== LOW Voltage detected
548    Wed Sep  5 12:06:39 2018  Fault     Fault     critical
      SP detected fault at time Wed Sep  5 12:06:39 2018. V_+1V2_VDD at /SYS/MB has exceeded low non-recoverable threshold.
547    Wed Sep  5 12:06:39 2018  IPMI      Log       major  
      ID =  900 : 09/05/2018 : 12:06:39 : Voltage : /MB/V_+1V2_VDD : Lower Critical going low  : reading 0.71 <= threshold 1.09 Volts
546    Wed Sep  5 12:06:18 2018  IPMI      Log       minor  
      ID =  800 : 09/05/2018 : 12:06:18 : Voltage : /MB/V_+1V2_VDD : Lower Non-critical going low  : reading 0.71 <= threshold 1.12 Volts
545    Wed Sep  5 12:05:54 2018  Chassis   Log       major  
      Host has been powered on                                                          <====== SERVER IS ON
544    Wed Sep  5 12:05:52 2018  Audit     Log       minor  
      root : Set : object = "/SYS/power_state" : value = "on" : success

 

+1V0_VDD
2303   Fri Jan 25 07:26:41 2019  IPMI      Log       minor          ID = ef00 : 01/25/2019 : 07:26:41 : Voltage : /MB/V_+1V0_VDD : Lower Non-critical going high : reading 1.00 >=

threshold 0.94 Volts
2298   Fri Jan 25 07:25:54 2019  IPMI      Log       minor          ID = ee00 : 01/25/2019 : 07:25:54 : Voltage : /MB/V_+1V0_VDD : Lower Non-critical going low  : reading 0.92 <=
threshold 0.94 Volts

 

 On some occasions you may also see fatal errors on one or more CPUs:

2300   Fri Jan 25 07:26:23 2019  Chassis   Log       major          Jan 25 07:26:23 ERROR: [CMP1  ] Received Fatal Error
2299   Fri Jan 25 07:26:23 2019  Chassis   Log       major          Jan 25 07:26:23 ERROR: [CMP0  ] Received Fatal Error

Or

2365   Mon Jan 28 06:58:51 2019  Fault     Fault     critical
      SP detected fault at time Mon Jan 28 06:58:51 2019. /SYS/MB/CMP1/P0 CPU causing reset errors
2364   Mon Jan 28 06:58:51 2019  Fault     Fault     critical
      SP detected fault at time Mon Jan 28 06:58:51 2019. /SYS/MB/CMP0/P0 CPU causing reset errors

 

Changes