SLIC card built as Service Module with type = SLIC the DSM / EPAP connections are not coming up.
(Doc ID 2459567.1)
Last updated on NOVEMBER 16, 2023
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 46.5 and laterInformation in this document applies to any platform.
Goal
I am running STP release 46.5.1.0.0-70.45.1 which has EPAP running. I replaced a SM4G card with SLIC card, and executed the following steps below. (As in a MOP Oracle delivered)
inh-card
chg-card:loc=1207:type=slic
init-flash:loc=1207:code=appr:gpl=BLSLC32
act-flash:Loc=1207
alw-card:Loc=1207
But the card is not available with SST "MPS Unavl", below is the status of the card and the MPS...please let me know if there is any steps missing.
> rept-stat-card:loc=1207:mode=full
tklcstp 18-10-03 10:22:34 CST EAGLE 46.5.1.0.0-70.45.1
rept-stat-card:loc=1207:mode=full
Command entered at terminal #17.
;
Command Accepted - Processing
tklcstp 18-10-03 10:22:34 CST EAGLE 46.5.1.0.0-70.45.1
CARD VERSION TYPE GPL PST SST AST
1207 140-042-000 SLIC SCCPHC IS-ANR MPS Unavl -----
ALARM STATUS = No Alarms.
BLSLC32 GPL version = 140-045-000
IMT BUS A = Conn
IMT BUS B = Conn
rept-stat-mps
tklcstp 18-10-03 10:38:42 CST EAGLE 46.5.1.0.0-70.45.1
rept-stat-mps
Command entered at terminal #17.
;
Command Accepted - Processing
tklcstp 18-10-03 10:38:42 CST EAGLE 46.5.1.0.0-70.45.1
VERSION PST SST AST
EPAP A 016-001-000 IS-NR Active -----
CRITICAL PLATFORM ALARM DATA = No Alarms
MAJOR PLATFORM ALARM DATA = No Alarms
MINOR PLATFORM ALARM DATA = No Alarms
CRITICAL APPLICATION ALARM DATA = No Alarms
MAJOR APPLICATION ALARM DATA = No Alarms
MINOR APPLICATION ALARM DATA = No Alarms
ALARM STATUS = No Alarms.
VERSION PST SST AST
EPAP B 016-001-000 IS-NR Standby -----
Solution
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Goal |
Solution |