SL8500/IBM/HP LTO - Tape Drive Bezel Issue and Audit Failure
(Doc ID 2464444.1)
Last updated on FEBRUARY 22, 2023
Applies to:
HP LTO6 Tape Drive - Version All Versions to All Versions [Release All Releases]Sun StorageTek SL8500 Modular Library System - Version All Versions and later
LTO Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Audit failure and drive state showing not functional from Sun StorageTek SL8500 Modular Library System.
Overview of the error reported from the library log snap shot:
1,2,1,1,1 HUJ5334DEW false false false Error HpUltrium6 46 empty J5ES-019.240 Fibre N/A 464970G+1535K80486 ok HP 50:01:04:f0:00:bb:20:e8 Legacy LOD-53
6909: 2018-10-18T12:37:13.895, 1.2.1.1.1, root, default, internal, 0, error, 3955, "Error from device Code: 604 - Drive is not functional", Data=controlPowererror6301<!|CDATA|Power on failed for drivetray||>604
FSC 6301: (FSC Match Found in Rev. FRS860)
The drive tray power up request failed
6913: 2018-10-18T12:37:13.996, 1.2.1.1.1, root, default, internal, 0, error, 1303, "Failure from drive Code: 604 - Drive is not functional", Data:=controlPowererror6301<!|CDATA|Power on failed for drivetray||>604
FSC 6301: (FSC Match Found in Rev. FRS860)
The drive tray power up request failed
13416: 2018-10-18T15:28:24.472, 1.2.1.1.1, root, default, reboot, 97201, error, 3204, "System error - Invalid state transition", state=Error transtion=Vary offline
13826: 2018-10-18T15:39:58.535, 1.2.1.1.1, root, hli0, move, 99101, error, 1116, "Drive is not online - checkState dst", hliLsm=1
Changes